A952
ONE SINGLE PRODUCT FOR EVERY APPLICATION
Thanks to the special spring system, with push and pull function depending on the type of installation (sliding or articulated arm), the A952 automation is characterized not only by the high level of security it can guarantee but also by its extreme versatility.
With a single automation, it is indeed possible to ‘transform’ swing doors by choosing from different uses - standard, emergency exit, fire resistance, or smoke evacuation - adaptable to many areas of applications such as education, airports, hospitals, but also hotels, residential, and offices.
Additional features such as: spring opening even in the event of mains power failure, mechanical coordinator for integrated double door closure, synchronized double door application, the SAFE FLOW/TOUCH FREE device allowing contactless entries, and finally the simple and intuitive programming display, make it the perfect solution for every application.
AN AUTOMATION THAT STACKS UP THE NUMBERS
PATENTED AND CERTIFIED SAFETY
THE BEST TECHNOLOGY BY FAAC
Do you have questions about our products?
Model |
A952 |
---|---|
Power supply voltage |
110 – 240 V~ 50/60 Hz |
Max power |
350 W |
Standby power |
5 W |
Use frequency |
100 % |
Electric motor |
24 V DC motor with encoder |
Max accessories load |
1 A – 24 V |
Electric lock power supply voltage |
(N.O./N.C.) 24 V / 500 mA max |
Dimensions (L × D × H) |
715 × 150 × 74 mm |
Weight |
12 kg |
Operation during power cut |
Manual push/pull opening – Spring closing |
Max leaf opening angle |
100° – 125° |
Opening & closing time |
4 – 10 s (adjustable) |
Partial opening adjustment |
10 % – 90 % of total opening |
Pause time |
0 – 30 s |
Night pause time |
0 – 90 s |
Encoder |
As standard |
Protection sensor monitoring (EN 16005) |
As standard (may be excluded) |
Low-energy movement (EN 16005) |
As standard (may be excluded) |
Operating ambient temperature |
–20 °C to +55 °C |
Protection class |
IP 23 (internal use only) |
Compliance with regulations |
EN 16005; EN 61000-6-2; EN 61000-6-3; EN 13849-1 Pl. D; EN 13849-2 |